hospital equipment manufacturer, hospital equipment supplier hospital equipment manufacturer, hospital equipment supplier hospital equipment supplier, hospital equipment exporter
hospital equipment manufacturer, hospital equipment supplier hospital equipment manufacturer, hospital equipment exporter
hospital equipment supplier, hospital equipment exporter SS Technomed SS Technomed
SS Technomed
SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed
SS Technomed

SS Technomed  Infant Health Care Products
SS Technomed
We offer a complete range of equipment to carefully nurture the infants in the most hygienic conditions.


SS Technomed SS Technomed SS Technomed
SS Technomed
Phototherapy Unit Double Surface
SS Technomed
SS Technomed
Phototherapy Unit Double Surface
Phototherapy Unit Double Surface

  • In the new born period i.e birth to one month, jaundice can pose a serious problem, because high level of the billirubin can permanently damage the brain. This indirect billirubin, which is not water soluble, can be decomposed to a harmless metabolic, which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate. This is achieved by exposing the infant to bright light (app. 4.5 micro watts/sq.cm/nm) in the range of 420 to 480nm wave length. This is used for treatment of Hyperbillirubiaemia in Neonates, which provides the light source in range of 420-480 nm wave length. Double surface Phototherapy Unit is the combination of over head phototherapy unit and under Surface Phototherapy unit.
  • Undersurface Phototherapy Unit
    • Baby Bassinet with fold down panels.
    • Head down position, on both sides.
    • Phototherapy Unit fitted at a distance of 300 mm from baby bed.
    • 4 Blue + 2 white tubes in Overhead Phototherapy Unit, giving choice of two kinds of tubes to use with.
    • 4nos of blue light tubes with higher intensity of light in therapeutic range and 2 nos of white light tubes.
    • 6 nos. of white light tubes with the facility to use 4 or 6 tubes at a time
    • Compact & mobile
SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed
Phototherapy Unit Single Surface (Overhead Unit)
SS Technomed
SS Technomed

  • Overhead Phototherapy Unit, giving choice of two kinds of tubes to use with
  • 4 nos of blue light tubes with higher intensity of light in therapeutic range and 2 nos of white light tubes.
  • 6 nos. of white light tubes with the facility to use 4 or 6 tubes at a time
  • Facility of height adjustment, so as to fit over an incubator or baby cot etc.
  • Fold up facility during inspection of neonates or storage.
  • Angle folding facility, for using along with radiant warmer.
  • Compact & mobile
Technical Specification:

Power Supply - 220 V, 50 Hz, 120/160 watts

Phototherapy Unit Single Surface Overhead Unit

SS Technomed
SS Technomed SS Technomed SS Technomed


SS Technomed SS Technomed SS Technomed
SS Technomed
CFL Phototherapy Unit
SS Technomed
SS Technomed
CFL Phototherapy Unit



  • CFL Provides the light intensity of 18 pw/cm2/nm (approx) at 45cm from Baby cot.
  • Choise of 6 Blue or 4 Blue + 2 white CFL lamps for treatment and inspection.
  • Height 120 cm to 160 cm from the base.
  • Head Tilting Facility from-1800 + 1800 (Continuous).
  • 3 swivel castors fixed on sleek T-shaped base.
  • Powder coated scratch and rust proof body.
  • Special mirror coated reflector for better reflection.
SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed
Infant Radiant Warmer
SS Technomed
SS Technomed

Model:- Tiana IRW 1723
SST Infant Warmers are designed to provide advance warming capabilities while using one touch operations to simplify procedures.

Immediately after delivery the new born baby experiences some degree of thermal instability as it comes from the mothers womb which has the stable environment to the cooler environment of the delivery room.

  • Available with a choice of thermal control system Skin/Manual control.
  • Two function control modes provide the clinician more flexibility while optimizing the thermal environment.
  • In addition, the Skin/ Air temperature display is larger then the other set temperature display.
  • Advance microprocessor controlled with self-check on the electronic circuit.
  • Digital display of patient temperature and soft touch display of control temperature.
  • Skin Temperature can be converted from Celsius to Fahrenheit by the push of a button.
  • The spacious baby bed incorporates easily drop down sides for maximum access to the patient.
  • The control panel is also the heart for a completely integrated alarm system with both audible and visual indicators in the event of Probe Fail, Skin High and Skin Low.
  • Power Fail.
  • Heater Fail.
Manual Mode:
  • Facility to converting the warmer from servo mode to manual mode for non-stop working.
  • In Manual mode warmer will start from 40% heat and can be increased upto 99% according to usage.
Heater Assembly:
  • The Heater assembly located above the cente r of the support structure consists of radiant heater and reflector with inbuilt halogen examination lamp for assessment of Infant Color.

Technical Specification:
Height 1850mm
Length 900mm
Width 700mm
Electrical Specification:
Power supply 200V/50Htz
Heater Power 650Watts
Fuse 5 Amp

Infant Radiant Warmer

SS Technomed
SS Technomed SS Technomed SS Technomed


SS Technomed SS Technomed SS Technomed
SS Technomed
Open Care System (Model:TIANA)
SS Technomed
SS Technomed
Open Care System Model TIANA
Open Care System Model TIANA

Microprocessor Controlled
  • The digital, microprocessor-based controller comes standard with a full spectrum of features.
  • The Tiana Open care System comes complete with automatic manual and baby (Servo) modes.
  • Two function control models provide the clinician more flexibility while optimizing the thermal environment.
  • Skin temperature display is larger then other set temperature display
  • Skin temperature display can be converted from °C to °F by the push of a buttom.
  • A full complement of alarm provides safety and convenience, with both audible and visual indicators in the event of:

    - High Temp. / Low Temp.
    - Set High / Set Low
    - Probe Failure
    - Power Failure
  • The system automatically starts the heating from 40% in manual mode and the same can be changed through settings upto 99%.
  • The High & Low temp. alarm settings can be adjusted according to the patient condition.
  • The Radiant Warmer features an independent ambient temperature probe which maximizes the heating efficiency across the range of operating temperature.
  • A big LCD is provided for more specific information & visualization of the heater power in manual and servo modes.
  • The system automatically converts from servo mode to manual mode in case of probe failure thus providing non stop working of the unit.
  • The spacious baby bed incorporates easily drop down sided for maximum access to the patient.
Heater Assembly:

The heater assembly located above the center of the support structure consists of an integral examination light and a 650 Watts heating system for quick warming and even distribution of heat on the baby bed.

The First Breath:
  • The open care system combines virtually all the technologies, which a caregiver may need for resuscitation.
  • The neonate can be supplied with a constant oxygen flow through the oxygen humidifier when connected to an oxygen cylinder (optional).
  • The motorized slow suction can be used with a simple flip of a switch
  • A digital apgar timer is standard, which signals when 1, 5 and 10 minutes have collapsed.

Technical Specification:
Height 1924mm
Length 884mm
Width 858mm
Electrical Specification:
Power supply 200V/50Htz
Heater Power 650Watts
Fuse 5 Amp
IEC COMPLIANT

SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed
Open Care System (TIANA-S)
SS Technomed
SS Technomed
Microprocessor Controlled

  • The digital, microprocessor-based controller comes standard with a full spectrum of features.
  • The Tiana Open Care System comes complete with automatic manual and baby (Servo) modes.
  • Two function control models provide the clinician more flexibility while optimizing the thermal environment.
  • Dual digital temperature display is larger then other set temperature display
  • Skin temperature display can be converted from °C to °F by the push of a bottom.
  • A full complement of alarm provides safety and convenience, with both audible and visual indicators in the event of:

    - High Temp. / Low Temp.
    - Set High / Set Low
    - Probe Failure
    - Power Failure
  • The system automatically starts the heating from 40% in manual mode and the same can be changed through settings upto 99%. This changed power will remain for 15 minutes only and after that it will become 40% automatically.
  • The High & Low temp. alarm settings can be adjusted according to the patient condition.
  • The Radiant Warmer features an independent ambient temperature probe which maximizes the heating efficiency across the range of operating temperature.
  • A big LCD is provided for more specific information & visualization of the heater power in manual and servo modes.
  • The system automatically converts from servo mode to manual mode in case of probe failure thus providing non stop working of the unit.
  • The spacious baby bed incorporates easily drop down sided for maximum access to the patient.
Heater Assembly:

The heater assembly located above the center of the support structure consists of an integral examination light and a 650 Watts heating system for quick warming and even distribution of heat on the baby bed.

The First Breath:
  • The open care system combines virtually all the technologies which a caregiver may need for resuscitation.
  • The neonate can be supplied with a constant oxygen flow through the oxygen humidifier when connected to an oxygen cylinder.
  • The motorized slow suction can be used with a simple flip of a switch
  • A digital apgar timer is standard, which signals when 1,5 and 10 minutes have elapsed.
Motorised Hi/Low System:

Utilizing the latest technology in motorised up and down mechanism for the movement of the baby bed for ease in doing procedures.

Technical Specification:
Height 1924mm
Length 884mm
Width 858mm
Electrical Specification:
Power supply 200V/50Htz
Heater Power 650Watts
Fuse 5 Amp
IEC COMPLIANT

Open Care System TIANA-S

SS Technomed
SS Technomed SS Technomed SS Technomed


SS Technomed SS Technomed SS Technomed
SS Technomed
Infant / Baby Incubator
SS Technomed
SS Technomed
Infant Baby Incubator


Microprocessor Controlled
  • The temp controlled unit is operated by advanced micro computer technology.
  • The three digital display indication provide the Set, Air and Skin Temperature.
  • The safety features are self test and alarm system which helps in detecting different failures
  • The removable heater and fan unit make it easy to clean and service.
  • In addition, the Skin/Air temperature display is larger then the other set temperature display.
  • Full visibility & accessibility of the baby is provided by the designed of acrylic hood.
  • A full complement of alarm provides safety convenience, with both audible and visual indicator.
    • Probe:- Activates if probe is open, short or unplugged seconds
    • Fan:- Activates by fan failure or slow rotation
    • Over Temperature:- Activates if the temperature sense 0.5 deg. Above the set temperature
    • Low temperature:- Activates if the temperature sense 0.5 deg. Blow the set temperature
    • Power Failure
    • Programmable Set High/ Set Low temp & mute time.
  • Humidification is provided with the help of ultrasonic nebulizier which gives a constant humidification in the hood.
  • A big storage space is provided at the bottom of the unit to keep consumables etc.
  • The unit rests on four big castors with brakes in the front caster.

Electrical Specification:
Power 200V/50Hz
Power consumption 300Watts
Chasis Leakage >500 Amp
Current Fuse 5 Amp




SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed
Neopuff™ Infant Resuscitator
SS Technomed
SS Technomed


The Neopuff™Infant Resuscitator is an easy - to - use manually operated, gas-powered resuscitator that provides optimal resuscitation with a safe and controlled peak inspiratory pressure (PIP) and a consistent and precise positive-end expiratory pressure (PEEP)

The Neopuff™ Infant Resuscitator will safely inflate the baby's lungs and provide optimum oxygenation by delivering consistent PIP with each breath to avoid the risks associated with under or over inflation at uncontrolled pressures. A consistent and precise PEEP is maintained throughout the resuscitation process, maintaining functional residual capacity (FRC) and recruitment of alveoli, which prevents lung collapse.

Easy-to-Use:
  • The experience, training and fatigue of the operator does not effect the delivered pressures.
  • The Neopuff™ can accept and deliver oxygen concentrations from 21 % to 100%.
  • The patient T-piece can be attached to neonatal masks or endotracheal tubes.
  • The fast acting manometer provides constant reassurance of mask seal and delivered PIP and PEEP.
Alternative Temporary Respiratory Support:
  • Consistent PEEP can be delivered to assist with breathing during transport or ventilator circuit changes.

Neopuff 153 Infant Resuscitator
Neopuff 153 Infant Resuscitator
SS Technomed
SS Technomed SS Technomed SS Technomed


SS Technomed SS Technomed SS Technomed
SS Technomed
Baby Bassenet (General)
SS Technomed
SS Technomed
Baby Bassenet General


General Model:

With head down position from both sides, IV stand and large shelf for placing monitors etc.









SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed SS Technomed SS Technomed
SS Technomed
SS Technomed
| |
| |
| |
SS Technomed
SS Technomed SS Technomed SS Technomed